Picture only for reference

RRC-SMB-UBC-M

Medical Standard Battery Charger for SMBus compliant Batteries

  • 의료용 싱글베이 고속 충전기
  • RRC20xx 또는 유사한 스마트 배터리용
  • RRC 배터리 최적화 충전 프로세스:
    • 긴 수명
    • 고속 충전
  • 쉬운 조작 – Plug and Play
  • 배터리 용량 자동 인식 및 보정 스마트 배터리
  • 전 세계 사용 가능 한 외부 power supplies
  • 국가별 AC 입력 케이블 사용 가능

더 많은 정보를 찾고 계십니까?

RRC-SMB-UBC-M

Specification RRC-SMB-UBC-M

Input
Voltage range19.00 - 26.00VDC
Current3.40A max.
Power65.00W
ProtectionOver current (fuse protected), under voltage
Output
Voltage range

0 - 17.40VDC

Current

0 – 4.80A

Voltage tolerance±1% max.
Current tolerance

±10% max. @1.00A, ±3% max. @4.00A

Protection

Short circuit, Over temperature shutdown, Input / Output over current

Environmental
CoolingConvection cooled
Temperature

Operating: 0°C to 40°C
Non-operating: -20°C to 80°C

Pressure & Altitude

Operating: 1060hPa to 540hPa (-382m to 5000m)
Non-operating: 1060hPa to 540hPA (-382m to 5000m)

HumidityOperating: 20% to 80% r.H.
Non-operating: 10% to 90% r.H.
General
Efficiency~95% to 100% load
Battery type

For standard battery packs in form factor RRC20xx or similar SMBus compliant batteries

Green procurementRoHS 2011/65/EU + 2015/863/EU
REACH 1907/2006
WEEE 2012/19/EU
Chinese RoHS
IndicatorMulti-color LED (green, red, orange)
Housing dimensions (LxWxH)151.00 x 90.00 x 43.00mm
Weight198g (without power supply)

One time Red/Orange/Green

Selftest: Charger is ready for use.

Red/Green blinking

Battery recognition and initialization.

Orange blinking

The battery is currently being calibrated.

Orange light

The inserted battery is of the correct type and is currently being charged.

Green light

The battery is charged and can be removed for use.

Red blinking

The battery is too hot or too cold to be charged without damage. If the battery is too cold it will be charged as soon as it has warmed up sufficiently. If the battery is too hot it should be removed to cool down.

Red light

The battery is damaged or it is a conventional battery which cannot be recharged.

 

In combination with included external AC/DC power supply (PS65M)

 

Regulatory approvals

EuropeEN62368-1 (CE)
 InternationalIEC62368-1 (CB)

Electromagnetic Emissions

EuropeEN55011, EN55032, level B
 USAFCC15 class B

Electromagnetic Immunity

ESD immunityEN/IEC61000-4-2
 Electromagnetic field immunity EN/IEC61000-4-3
 EFT / BurstEN/IEC61000-4-4
 Surge

EN/IEC61000-4-5

 Conducted Immunity

EN/IEC61000-4-6

 Magnetic Fields

EN/IEC61000-4-8

 Voltage dips, short instrumentations & voltage variations

EN/IEC61000-4-11

 Immunity characteristics

EN55024

Specification external AC/DC power supply (PS65M)

Input

Voltage range

100.00 - 240.00VAC, 50 to 60 Hz

Current

1.60A max.

Stand by power

< 0.21W @ no load

Output
Voltage range

19.00VDC ± 5%

Power

65.17W max.

Current range

3.43A

Protection

Over voltage, over current, short circuit

Environmental
Temperature

Operating: 0°C to 40°C
Non-operating: -10°C to 70°C

General
EfficiencyCalifornia's Energy Efficiency Level VI

Ripple & Noise

0.19V (p-p)

Standard output connector

DC barrel jack, 5.5 x 2.5 x 11mm

Housing dimensions (LxWxH)

119.00 x 60.00 x 36.00mm, without cables and connectors

Weight

310g, without input cable

Cable length1500mm ±30mm
SafetyITECE, PSE
 MedicalcULus, T-mark. EN/IEC60601-1
EMIEuropeCE
 USA & CanadaFCC15 class B
 United KingdomUKCA
 MoroccoCMIM

Standard Battery Charger RRC-SMB-UBC-M is approved worldwide