Picture only for reference

RRC-SMB-UBC

Standard Battery Charger for SMBus Compliant Batteries

  • 60W Single bay fast charger
  • For the standard battery form factors RRC20xx or smart batteries with a similar footprint
  • Optimized charging process for RRC batteries
    • Longer cycle life
    • Faster charging
  • Simple operation – Plug and Play
  • Automatic recognition and calibration of smart battery learned capacity
  • External power supply for worldwide use
  • Country specific AC input cables available
  • Optional DC/DC car adapter available

Are you looking for more information?

RRC-SMB-UBC

Specification RRC-SMB-UBC

Input
Voltage range19.00 - 26.00VDC
Current3.40A max.
Power65.00W
ProtectionOver current (fuse protected), under voltage
Output
Voltage range

0 - 17.40VDC

Current

0 – 4.80A

Voltage tolerance±1% max.
Current tolerance

±10% max. @1.00A, ±3% max. @4.00A

Protection

Short circuit, Over temperature shutdown, Input / Output over current

Environmental
CoolingConvection cooled
Temperature

Operating: 0°C to 40°C
Non-operating: -30°C to 80°C

Pressure & Altitude

Operating: 1060hPa to 795hPa (-382m to 2000m)
Non-operating: 1060hPa to 533hPA (-382m to 5000m)

HumidityOperating: 8% to 90% r.H.
Non-operating: 5% to 95% r.H.
General
Efficiency~95% to 100% load
Battery type

For standard battery packs in form factor RRC20XX or similar SMBus compliant batteries

Green procurementRoHS 2011/65/EU + 2015/863/EU
REACH 1907/2006
WEEE 2012/19/EU
Chinese RoHS
IndicatorMulti-color LED (green, red, orange)
Housing dimensions (LxWxH)151.00 x 90.00 x 43.00mm
Weight198g (without power supply)

One time Red/Orange/Green

Selftest: Charger is ready for use.

Red/Green blinking

Battery recognition and initialization.

Orange blinking

The battery is currently being calibrated.

Orange light

The inserted battery is of the correct type and is currently being charged.

Green light

The battery is charged and can be removed for use.

Red blinking

The battery is too hot or too cold to be charged without damage. If the battery is too cold it will be charged as soon as it has warmed up sufficiently. If the battery is too hot it should be removed to cool down.

Red light

The battery is damaged or it is a conventional battery which cannot be recharged.

 

In combination with included external AC/DC power supply (PS65)

 

Regulatory approvals

EuropeEN62368-1 (CE)
 InternationalIEC62368-1 (CB)

Electromagnetic Emissions

EuropeEN55011, EN55032, level B
 USAFCC15, class B

Electromagnetic Immunity

ESD immunityEN/IEC61000-4-2
 Electromagnetic field immunity EN/IEC61000-4-3
 EFT / BurstEN/IEC61000-4-4
 Surge

EN/IEC61000-4-5

 Conducted Immunity

EN/IEC61000-4-6

 Magnetic Fields

EN/IEC61000-4-8

 Voltage dips, short instrumentations & voltage variations

EN/IEC61000-4-11

 Immunity characteristics

EN55024

Specification external AC/DC power supply (PS65)

Input

Voltage range

100.00 - 240.00VAC ±10%, 50-60Hz

Current

1.70A max.

Stand by power

< 0.21W @ no load
Output
Voltage range

19.00VDC ± 5%

Power

65.00W max.

Current range

3.42A max.

Protection

Over voltage, over current, short circuit, over temperature

Environmental
Temperature

Operating: 0°C to 40°C
Non-operating: -10°C to 70°C

General
Efficiency

California's Energy Efficiency Level VI

Ripple & Noise

0.30V (p-p)

Standard output connector

DC barrel jack, 5.5 x 2.5 x 11mm

Housing dimensions (LxWxH)

95.00 x 50.00 x 25.40mm

Weight

270g

Cable length1600mm ±50mm

Approvals

EuropeCE
 InternationalCB
 USA & CanadacULus
 

Australia & New Zealand

RCM
 Russia & Eurasian Customs UnionEAC
 KoreaKC
 ChinaCCC
 JapanPSE
 IndiaBIS
 TaiwanBSMI
 MexicoNOM
 ArgentinaIRAM
 South AfricaSABS
 SingaporeSafety Mark
 United KingdomUKCA
 MoroccoCMIM

Standard Battery Charger RRC-SMB-UBC is approved worldwide