Picture only for reference

RRC-SMB-UBC-DIS

Standard Battery conditioner for SMBus compatible Batteries

  • Ensures batteries are discharge to 30% state of charge (or less) for transportation
  • Places batteries in very low power mode called “ship mode” to limit self-discharge
  • For the standard battery form factors RRC20xx or smart batteries with a similar footprint
  • Simple operation – Plug and Play
  • Automatic recognition and calibration of smart battery learned capacity
  • External power supply for worldwide use
  • Country specific AC input cables available
  • Optional DC/DC car adapter available

Are you looking for more information?

RRC-SMB-UBC-DIS

Specification RRC-SMB-UBC-DIS

Input 
Voltage range19.00 – 26.00VDC
Current3.40A max.
Power65.00W
ProtectionOver current (fuse protected), under voltage
Output 
Voltage range0 - 17.40VDC
Current range0 - 4.80A
Voltage tolerance±1% max.
Current tolerance±10% max. @1.00A, ±3% max. @4.00A
Charge power60.00W max.
ProtectionShort circuit, over temperature shutdown, input-/output over current
Environmental  
 Operation:Storage:
Ambient Temperature0°C to 40°C-30°C to 80°C
Pressure and Altitude

1060hPa to 533hPa

-382m to 5000m

1060hPa to 533hPa

-382m to 5000m

Humidity (non-condensing)8% to 90% r.H.5% to 95% r.H.
General 
Efficiency~95% at 100% load
IndicatorMulti-color LED (green, red, orange)
Battery typesStandard battery form factors RRC20x or smart batteries with a similar footprint
Green procurement

RoHS 2011/65/EU + 2015/863

REACH 1907/2006

WEEE 2012/19/EU

Chinese RoHS

CoolingConvection cooled
One time Red/Orange/GreenSelf-test: Charger is ready for use.
Green/Red blinkingCharger identifies inserted battery.
OrangeProgress indication – The battery is being charged.
Orange blinkingProgress indication – The battery is being discharged.
GreenSuccess indication - The battery successfully charged/discharged to transport State of Charge and is set into ship mode.
RedError indication - The battery was not successfully charged/discharged to transport State of Charge or is not set into ship mode.
Red blinkingThe temperature of the battery is too low or too high.
Housing dimensions (LxWxH)151 x 90 x 43mm
Weight198g (excluding power supply)

In combination with included external AC/DC power supply

Regulatory approvalsEuropeEN62368-1 (CE)
 InternationalIEC62368-1 (CB)
Electromagnetic EmissionsEuropeEN55011, EN55032, level B
 USAFCC15 class B
Electromagnetic ImmunityESD immunityEN/IEC61000-4-2
 Electromagnetic field immunityEN/IEC61000-4-3
 EFT / BurstEN/IEC61000-4-4
 SurgeEN/IEC61000-4-5
 Conducted ImmunityEN/IEC61000-4-6
 Magnetic FieldsEN/IEC61000-4-8
 Voltage dips, short instrumentations & volt-age variationsEN/IEC61000-4-11
 Immunity characteristicsEN55024

Specification external AC/DC power supply

Input 
Voltage range100.00 – 240.00VAC ±10%, 50-60Hz
Current1.70A max.
Stand by power< 0.21W @ no load
Output 
Voltage range19.00VDC ± 10%
Power65.00W max.
Current range3.40A max.
ProtectionShort circuit, over voltage, over current, over temperature
EfficiencyCalifornia's Energy Efficiency Level VI
Ripple & Noise0.30V (p-p)
Standard output connectorDC barrel jack, 5.5 x 2.5mm
Housing dimensions (LxWxH)95 x 50 x 25.4mm
Weight270g
Cable length1600mm
ApprovalsEuropeCE
 InternationalCB
 USA & CanadacULus
 Australia & New ZealandRCM
 Russia (Customs Union)EAC
 KoreaKC
 ChinaCCC
 JapanPSE
 IndiaBIS
 TaiwanBSMI
 MexicoNOM
 ArgentinaIRAM
 South AfricaSABS
 SingaporeSafety Mark
 United KingdomUKCA
 MoroccoCMIM

Standard battery conditioner RRC-SMB-UBC-DIS is approved worldwide