Der 60 Watt Auto-Adapter CAR4A mit Car/Truck Eingangsstecker.

CAR4A

60 Watt automobile power adapter

  • Wide input voltage range 9-32V
  • Max. output power 72 Watt
  • Individual output connector on request
  • Car/Truck input connector

Are you looking for more information?

Downloads CAR4A

CAR4A

Specification

Input
Voltage range10.50 -32.00VDC
Standby currentTypical 77.00mA @ 10.50V input
Typical 54.00mA @ 32.00V input
Input fuse10.00A
ProtectionReverse polarity (input fuse),
Under voltage protection (Transient suppression circuit)
Output
Voltage range3.00 - 24.00V nominal
Power

60.00W cont.
72.00W max.

Initial set tolerance

±5% max.

Load regulation

- 0.10V max. / A

Line regulation

±1% max.

Ripple & noise

< 0.30mV pk-pk

Current limitConstant current, 4.00A max.
Protection

Short circuit
Over temperature 
Over voltage 

Environmental

CoolingConvection cooled
Temperature

Operating: -20°C to 35°C
35°C to 50°C, derating 35%

Non-operating: -40°C to 85°C

Pressure & altitude

Operating: 1200hPa to 570hPa (max. 4600m above sea level)
Non-operating: 1200hPa to 115hPa (max. 15000m above sea level)

Humidity5 to 95% r.H., non condensing
General
Input connector

Cigarette lighter adapter

Output connector

Customer-specific

Efficiency

typical 86% at 100% load

MTBF

20000h @ 25°C ambient temperature and GB per MIL-HDBK217F

Green procurementRoHS 2011/65/EU + 2015/863/EU
REACH 1907/2006
WEEE 2012/19/EU
IndicatorSingle green LED
Ingress protection rating

IEC60529, IP40

Regulatory approvalsEuropeCE
 United KingdomUKCA
 USA & CanadaUL60950-1
 Australia & New ZealandRCM
Electromagnetic emissionsEurope

EN55011/EN55022 classB, EN55024, EN55014-1

 USA & CanadaFCC15 class B
Electromagnetic immunityESD immunity

IEC61000-4-2, 4kV contact, 8kV air

 Electromagnetic field immunity

IEC61000-4-3, 80-1000MHz, 10V/m, AM 80% 1kHz, PM ED50% 200Hz

 Electrical fast transient/burst immunity test

IEC61000-4-4, +/-1kV, 5/50ns

 Surge immunity test

IEC61000-4-5, +/-0.5kVsym, 1.2/50(8/20)μs

 Conducted Immunity

IEC61000-4-6, 0.15-80MHz, 10V, 80%, 1KHz, AM, CDN-M2

 Immunity

IEC61000-6-1

 Impulses

DIN40839 part 1

- Other approvals on request

Housing dimensions (LxWxH)

111.00 x 48.00 x 35.00mm, without cables and connectors

Input cable length

100cm ±5%

Output cable length

100cm ±5%

Weight

approx. 200g, without cables, connectors and wall-mount kit


Approvals CAR4A

United Kingdom
China