Der 60 Watt Auto-Adapter CAR4A mit Car/Truck Eingangsstecker.

CAR4A

60 Watt Auto-Adapter

  • Weiter Eingangsspannungsbereich von 9-32V
  • Max. Ausgangsleistung 72 Watt
  • Individueller Ausgangsstecker konfigurierbar
  • Car/Truck Eingangsstecker

Sie möchten weitere Informationen?

Downloads CAR4A

Produktdatenblatt CAR4A

Specification

Input

Voltage range

10.50 - 32.00VDC

Standby currentTypical 77.00mA @ 10.50V input
Typical 54.00mA @ 32.00V input
Input fuse10.00A
ProtectionReverse polarity (input fuse),
Under voltage protection (Transient suppression circuit)

 

Output
Voltage range3.00 - 24.00V nominal
Power

60.00W cont.
72.00W max.

Initial set tolerance

±5% max.

Load regulation

- 0.10V max. / A

Line regulation

±1% max.

Ripple & noise

< 0.30V pk-pk

Current limitConstant current, 4.00A max.
Protection

Short circuit
Over temperature 
Over voltage 

 

Environmental

CoolingConvection cooled
Temperature

Operating: -20°C to 35°C (35°C to 50°C, derating 35%)
Non-operating: -40°C to 85°C

Pressure & altitude

Operating: 1200hPa to 570hPa (max. 4600m above sea level)
Non-operating: 1200hPa to 115hPa (max. 15000m above sea level)

Humidity5 to 95% r.H., non condensing

 

General
Input connector

Cigarette lighter adapter

Output connector

Customer-specific

Efficiency

typical 86% at 100% load

MTBF

20000h @ 25°C ambient temperature and GB per MIL-HDBK217F

Green procurement

RoHS 2011/65/EU + 2015/863/EU
REACH 1907/2006
WEEE 2012/19/EU

IndicatorSingle green LED
Ingress protection rating

IEC60529, IP40

 

Regulatory approvalsEuropeCE
 United KingdomUKCA
 USA & CanadaUL60950-1
 Australia & New ZealandRCM
Electromagnetic emissionsEurope

EN55011/EN55022 classB, EN55024, EN55014-1

 USA & CanadaFCC15 class B
Electromagnetic immunityESD immunity

IEC61000-4-2, 4kV contact, 8kV air

 Electromagnetic field immunity

IEC61000-4-3, 80-1000MHz, 10V/m, AM 80% 1kHz, PM ED50% 200Hz

 Electrical fast transient/burst immunity test

IEC61000-4-4, +/-1kV, 5/50ns

 Surge immunity test

IEC61000-4-5, +/-0.5kVsym, 1.2/50(8/20)μs

 Conducted Immunity

IEC61000-4-6, 0.15-80MHz, 10V, 80%, 1KHz, AM, CDN-M2

 Immunity

IEC61000-6-1

 Impulses

DIN40839 part 1

- Other approvals on request

Housing dimensions (LxWxH)

111.00 x 48.00 x 35.00mm, without cables and connectors

Input cable length

100cm ±5%

Output cable length

100cm ±5%

Weight

approx. 200g, without cables, connectors and wall-mount kit


Zulassungen CAR4A