RRC-SMB-HBC

Standard-Batterieladegerät für SMBus kompatible Batterien

  • 120W Schnellladegerät mit einem Ladeschacht
  • Für RRC3570 Standard-Batteriepacks
  • Optimiertes Ladeverfahren für RRC-Batterien:
    • Längere Zykluslebensdauer
    • Schnelleres Laden
  • Einfache Bedienung - Plug and Play
  • Externe Stromversorgung für den weltweiten Einsatz
  • Länderspezifische AC-Eingangskabel verfügbar

Sie möchten weitere Informationen?

Produktdatenblatt RRC-SMB-HBC

Specification RRC-SMB-HBC

Input
Voltage range19.00 - 24.00VDC
Current10.00A max.
Power

180.00W max. (dependent on power supply)

Output
Voltage range

0 - 29.40VDC

Current

0 – 6.00A

Voltage tolerance±1% max.
Current tolerance

±10% max. @1.00A, ±3% max. @4.00A

Charge power

180.00W max.

Protection

Short circuit, overtemperature shutdown,
Input / output overcurrent

Environmental
CoolingConvection cooled
Ambient temperature

Operating: 0°C bis 40°C
Storage: -30°C to 80°C

Pressure & altitude

Operating: 1060hPa to 795hPa (-382m to 2000m)
Storage: 1060hPa to 533hPA (-382m to 5000m)

Humidity (non-condensing)Operating: 8% to 90% r.H.
Non-operating: 5% to 95% r.H.
General
Efficiency~95% to 100% load
Battery type

Standard battery form factors RRC35xx or smart batteries with a similar footprint

Green procurement

RoHS 2011/65/EU + 2015/863/EU
REACH 1907/2006
WEEE 2012/19/EU
Chinese RoHS

IndicatorMulti-color LED
Housing dimensions (LxWxH)

TBC

WeightTBC
 

In combination with included external AC/DC power supply

 

Regulatory approvals

EuropeEN62368-1 (CE)
 InternationalIEC62368-1 (CB)

Electromagnetic emissions

EuropeEN55011, EN55032, level B
 USAFCC15 class B

Electromagnetic immunity

ESD immunityEN/IEC61000-4-2
 Electromagnetic field immunity EN/IEC61000-4-3
 EFT / burstEN/IEC61000-4-4
 Surge

EN/IEC61000-4-5

 Conducted immunity

EN/IEC61000-4-6

 Magnetic fields

EN/IEC61000-4-8

 Voltage dips, short instrumentations & voltage variations

EN/IEC61000-4-11

 Immunity characteristics

EN55035

Specification external AC/DC power supply

Input

Voltage range

100.00 - 240.00VAC ±10%, 50-60Hz

Current

TBC

Standby power

TBC
Output
Voltage range

TBC

Power

120.00W max.

Current range

TBC

Protection

Short circuit, over-voltage, over-current, over temperature

General
Efficiency

California's Energy Efficiency Level VI

Ripple & noise

300mV (p-p)

Standard output connector

DC barrel jack, 5.50 x 2.50 x 11.00mm

Housing dimensions (LxWxH)

TBC

Weight

TBC

Cable lengthTBC

Approvals

EuropeCE
 InternationalCB
 USA & CanadacULus
 Australia & New ZealandRCM
 Russia & Eurasian Customs UnionEAC
 KoreaKC
 ChinaCCC
 JapanPSE
 IndiaBIS
 

Taiwan

BSMI
 MexicoNOM
 ArgentinaIRAM
 South AfricaSABS
 SingaporeSafety Mark
 United KingdomUKCA
 MoroccoCMIM
 ArgentinaS-Mark

Das Standard Batterieladegerät RRC-SMB-HBC ist weltweit zugelassen